The control box has an F3 where the volts are usually at. I don't know what that means, or how to fix it.
IS THERE ANY WAY TO BYPASS THE CONTROLER BOX
The SQF Package has a standard SQ pump inside that runs from AC only. The majority of SQ pumps are 240vac. The SQ pump does have electronics inside for soft starting and detecting that water is there. A few other things also. If this was bought as a package the SQF, then you can feed 240 in to test it without the SQF electronics (you need to disconnect them!!!). The other thing is your well could be dry.The Grundfos SQLFlex takes a wide range of AC or DC input because it uses a rectifier to get DC and then uses that DC to power an inverter that delivers exactly what voltage and frequency the pump motor needs to use up the available power.
I do not think that the inverter is in the pump (I may be wrong), but rather in the controller. That means that bypassing the controller is very likely to damage the pump beyond repair, as the pump would want to run on correctly pulsed AC.